Reactor Specifications |
| General |
| Deposition rate |
0.3 to 1.1 micron/hour (recipe and part geometry dependent) |
| Useful deposition area |
140 square inches typical |
| Power consumption |
Approx. 35 kW plus vacuum pump |
| MTBF |
>500 hours |
| Run turn-around time |
<1 hour |
| Preventive maintenance downtime |
Approx. 2% for cleaning and pump maintenance |
| Unscheduled downtime |
<5% |
| Process Control, Model 600P |
| Gas cabinet configuration |
4 MFC loops: CH4, 2 x H2, N2. |
| Gas flow rate |
Methane: 200 SCCM.
Hydrogen: high flow 5 SLM.
Hydrogen: low flow, 500 SCCM.
Nitrogen: 10 SLM. |
| Recipe control |
Up to 59 steps, AutoMode plus Manual Mode; real-time display of all parameters; datalogging of all exceptions to host supervisor; all parameters adjustable in each step. |
| Pressure control |
Downstream closed loop throttle valve. |
| Process Control, Model 600RD |
| Gas cabinet configuration |
5 MFC loops: CH4, 2 x H2, N2, Ar. |
| Gas flow rate |
Methane: 200 SCCM.
Hydrogen: high flow 5 SLM.
Hydrogen: low flow, 100 SCCM.
Nitrogen: 10 SLM.
Argon: 5 SLM. |
| Recipe control |
Up to 59 steps, AutoMode plus Manual Mode; real-time display of all parameters; datalogging of all exceptions to host supervisor; all parameters adjustable in each step. |
| Pressure control |
Downstream closed loop throttle valve. |
| Host Supervisor |
| Included with first system |
Workstation can control up to four Model 600 Reactors. Provides system monitoring and control, data logging, and recipe development and storage. |
| Vacuum System (Optional) |
| Pump type |
Alcatel 2063 or equivalent. |
| Pump footprint |
12 in. x 34 in.(30 cm x 86 cm). |
| Cycle time |
30 minute pump-down; 10 minute vent. |
| Operating range |
10 to 50 Torr. |
| Accuracy |
±500 mTorr. |
| Leak test |
Software controlled, optional on every run. |
| Safety |
| Hardware interlocks |
Equipment and personnel protected from hazardous situations related to flammable gas, high voltages and high temperatures. (External flammable gas detector required.) |
| Software interlocks |
User-controlled through Alarm/Abort Levels on analog values and status of digital alarm inputs. |
| Facilities Requirement |
| Footprint |
48 in. x 54 in. (117 cm x 132 cm) |
| Power input |
480 VAC 3-phase, 4-wire, 70 Amp.
208 VAC 3-phase, 5-wire, 20 Amp. |
| Cooling water |
10 gpm at 40 psi drop, 20°C maximum |
| Access |
24 in.(60 cm) clearance, all sides. |
| Process gases |
H2, CH4, N2 and Ar. |